Design Guide - Dual Standard Installation
DUAL STANDARD INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
*83 1/2" min.
*84 1/2" max.
(212.1-214.6 cm)
*Trim will overlap
additional 5/8".
18"
(45.7 cm)
8"
(20.3 cm)
(22.9 cm)
ELECTRIC
Water And Electrical Locations
Electrical and water supply must be located as shown.
For 24" Deep Cutouts
A trim kit (ZKW72V) is required for standard
installations.
Heater Unification Kit ZKMV required
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Refer to Dim A on page 6 for clearances needed for
door swing.
31-1000600 Rev. 0
71 1/2" (181.6 cm)
54"
(137.2 cm)
44"
(111.8 cm)
9"
(22.9 cm)
9"
9"
(22.9 cm)
ELECTRIC
WATER
6" (15.2 cm)
Finished
Return on
both sides
and top
9"
(22.9 cm)
WATER
6" (15.2 cm)
2 1/2" (6.4 cm)
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4" O.D. copper tubing or
QuickConnect
water line and water connection location, long enough
to extend to the front of the unit (8' [2.4m]). Installation
of an easily accessible shut-off valve in the water line
is required.
31
24" (61 cm)
kit (WX08X10006) between the cold