35325 Mücke, Germany
If the scheduled service is overdue, a service due message
appears on the screen as soon as the unit is plugged into
the mains or generator power supply. This message has to
be acknowledged by pressing START/SET.
9.2
Measuring Resistance
When the START/SET key was pressed to initiate a welding
process, the resistance value of the fitting is measured and
compared to the value entered as part of the read fitting
code. If the gap between the two values is smaller than
the acceptable tolerance given in the code, the welding
process starts. If the gap is greater than the preset tol-
erance, the welding unit aborts welding and displays a
"Resistance Error" message. Furthermore, it displays the
actual resistance value measured for the connected fitting.
The reason for a resistance error may be poorly contacting
and/or worn connection terminals. Therefore, if this error
occurs, check them for proper fit and, if worn, replace
them with new ones.
9.3
Overheating Switch
The welding process aborts if the temperature of the
transformer in the welding unit is too high. The overheat-
ing circuit breaker for the transformer stops the welding
if the temperature reading is too high and the remaining
welding time is longer than 800 seconds. The display and
the welding report will show an "Overheated" message.
9.4
Indication of Power Supply Failure at the Last
Welding
The message "Power Supply Failure Last Welding" indicates
that the previous welding aborted because of a power
supply failure. The reason may be too weak a generator
or too long or too thin an extension cable, or a tripped
cut-out in the mounting box. The next welding operation
is still possible after acknowledging the message by press-
ing the STOP/RESET key.
10
Configuring the Welding Unit
With the operator identity card, the welding unit can be
reconfigured. When the MENU key is pressed, the "Enter
Menu Code" message appears on the screen. After the
code was read from the operator card, the selection menu
in Display 15 shows.
Version September 2022
HÜRNER HST 300 HP 2.0 User's Manual
>Settings
-M-
Recording
-M-
Display 15
EN