12.3 Place of installation of the stove
In the product handbook annexed are indicated the
minimum distances with respect to the combustible
materials and articles expressed in cm that must be
respected while positioning the stove.
Protect all structures which could ignite if exposed
to excessive heat.
Floors consisting of flammable material such as
for example: wood, parquet, linoleum, laminate or
covered with carpets, must be protected by a flame
retardant base under the stove, of a sufficient size.
This base can be, for example, in steel, pressed slate,
glass or stone and must cover the floor in the area
below the stove and the flue c onnecting p ipe a nd
must protrude at least 50 cm in front.
The manufacturer declines all responsibility for
any variations in the characteristics of the material
constituting the floor under the protection.
Any wooden elements (e.g. beams) or combustible
materials located near the stove must be protected
with fireproof material.
Flammable walls or elements must be kept at a
distance of at least 80 cm from the stove.
Provide a technical space accessible for
maintenance.
Remember to respect the minimum distance from
flammable materials (x) shown on the identification
plate of the pipes used to make the chimney (Fig.
5.3).
Pi = Flammable wall
Pp = Floor protection

12.4 Combustion air

The stove, during its operation, draws a quantity of air
from the environment in which it is placed (with the
exception of the products of the hermetic series that
can take it directly from the outside); this air must be
reintegrated through an air intake outside the room
itself (Fig. 5.4a - PA = Air Intake).
If the rear wall of the stove is an external wall, create
a hole for suction of the combustion air at a height of
approximately 20-30 cm from the ground, respecting
the dimensional indications provided in the product
technical sheet at the end of the manual.
A non-closable permanent aeration grid must be
placed external; in areas that are particularly windy
and exposed to weathering, provide rain and wind
protection.
Make sure the air intake is positioned so that it is not
accidentally obstructed.
If it is impossible to create the external air intake in
the rear wall of the stove (non-perimeter wall) a hole
must be created in an external wall of the room where
26
Pi
Pi
80 cm
Pp
004778270 - 24/07/2020
Fig. 5.3
PA
Fig. 5.4a