Fronius Datamanager 2.0; Controls, Connections, And Indicators On The Fronius Datamanager - Fronius Symo 10.0-3 208-240 Instructions De Service

Masquer les pouces Voir aussi pour Symo 10.0-3 208-240:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fronius Datamanager 2.0

Controls, Con-
nections, and In-
dicators on the
Fronius Dataman-
ager
No. Function
(1)
(10)
(9)
(8)
IP switch
For changing the IP address:
Switch position A
Specified IP address and opening the WLAN Access Point
Fronius Datamanager 2.0 uses fixed IP address 169.254.0.180 for a direct con-
nection to a PC via LAN.
If the IP switch is set to position A, an Access Point for a direct WLAN connec-
tion to Fronius Datamanager 2.0 is also opened.
Access data for this Access Point:
Network name: FRONIUS_240.XXXXXX
Key: 12345678
Fronius Datamanager 2.0 can be accessed:
-
via DNS name "http://datamanager"
-
via IP address 169.254.0.180 for the LAN interface
-
via IP address 192.168.250.181 for the WLAN Access Point
Switch position B
Assigned IP address
Fronius Datamanager 2.0 operates using an assigned IP address (factory set-
ting DHCP dynamic).
The IP address can be set at the Fronius Datamanager 2.0 website.
(1)
(2)
(3)
(7)
(6)
(5)
(4)
19

Publicité

Table des Matières
loading

Table des Matières