601
CAN bus is full
603
AC module temperature sensor faulty
(L3)
DC module temperature sensor faulty
604
607
RCMU fault
608
Function incompatibility (one or more PC
boards in the inverter are not compatible
with each other, e.g., after PC board re-
placement)
*) If status code persists: Contact a Fronius-trained service technician
**) Fault is corrected automatically. If this status code keeps recurring, contact your system
installer
Class 7 Status
Class 7 status codes concern the inverter control unit, configuration and data recording,
Codes
and can directly or indirectly affect grid power feed operation.
Code
Description
701–
Provides information about the
704
internal processor status
Conflict when setting the in-
705
verter number (e.g., number
assigned twice)
706–
Provides information about the
716
internal processor status
721
EEPROM was reinitialized
722–
Provides information about the
730
internal processor status
Initialization error – USB flash
731
drive is not supported
Initialization error – overcurrent
732
at USB flash drive
733
No USB flash drive inserted
Behavior
Inverter does not feed ener-
gy into the grid.
The inverter will automati-
cally attempt to connect
again and, if possible, re-
sume feeding energy into
the grid
Inverter does not feed ener-
gy into the grid.
Inverter does not feed ener-
gy into the grid.
Behavior
Warning message on the
display
-
Warning message on the
display
Warning message on the
display
Warning message on the
display
Warning message on the
display
Warning message on the
display
Remedy
Update inverter firm-
ware; *)
*)
Reset the status code by
pressing the "Enter" key.
The inverter resumes
feeding energy into the
grid; if the status code
keeps recurring, check
the entire affected pho-
tovoltaic system for any
damage; **)
Update inverter firm-
ware; *)
Remedy
*)
Correct inverter number in the
setup menu
*)
Acknowledge status code; *)
*)
Check or replace USB flash drive
Check the USB flash drive file
system; *)
Insert or check USB flash drive; *)
55

Publicité

Table des Matières
loading

Table des Matières