Relay Mode
communications area:
-
-
-
Setting range
Factory setting
Relay test
Switch on point (only if "Energy manager" function is activated )
switched on
Factory setting
Setting range
Switch off point (only if the "Energy manager" function is activated)
switched off
Factory setting
Setting range
Energy Manager
The "Energy Manager" function can be used to trigger the potential-free switch contact so
(in Relay Menu
that it functions as an actuator.
Item)
A user connected to the potential-free switch contact can thus be controlled by assigning
a power feed dependent switch-on or switch-off point.
The potential-free switch contact is switched off automatically:
-
-
-
-
36
For selection of the various functions of the potential-free switching contact in the data
Alarm function
Active output
Energy manager
Alarm function:
Permanent /
Switches the potential-free switching contacts for continual and tem-
ALL:
porary service codes (e.g., brief interruption of grid power feed opera-
tion, a service code occurs a set number of times per day – can be set
in the "BASIC" menu)
Active output:
ON:
The potential-free switching contact NO is switched on at all times
while the inverter is operating (as long as the display lights up or ap-
pears)
OFF:
The potential-free switching contact NO is switched off
Energy manager:
E-manager:
You can find additional information on the "Energy manager" function
in the "Energy Manager" section below
Functional test to check if the potential-free switching contact works
for setting the effective power limit from which the potential-free switching contact will be
for setting the effective power limit from which the potential-free switching contact will be
When no current is being fed into the public grid supply by the inverter
When the inverter is switched manually to standby mode
When there is an effective power assignment of 10% of the power rating
When there is insufficient solar radiation
ALL / Permanent / OFF / ON / E-manager
ALL
1000 W
Switch off point – max. power rating of the inverter / W / kW
500
0 – switch on point / W / kW