Télécharger Imprimer la page

Burkert BVS 14 ATEX E 008 X Instruction Supplémentaire page 8

Masquer les pouces Voir aussi pour BVS 14 ATEX E 008 X:

Publicité

Les langues disponibles

Les langues disponibles

Approval sticker
ATEX approval number
eXAm 13 AteX XXXXX
ii 2G ex ia iic t4 Gb
ii 2d ex ia iiic t135°c db iP64/67
iecex eXAm 13.XXXXX
ex ia iic t4 Gb
ex ia iiic t135°c db iP64/67
Marking gas explosion protection
ii 2G ex ia iic t4 Gb
ii 2d ex ia iiic t135°c db iP64/67
Ignition degree of protection
Marking dust explosion protection
Fig. 3:
Example approval sticker
8
ce0102
ATEX marking
IECEx approval number
IECEx marking
Degree of protection
Equipment protection level
Temperature class
Gas group
English
BVS 14 ATEX E 008 X / E 052 X
Particularsafetyinstructions
4.1.6
Temperature ranges in
explosion-risk areas
Ambient temperature
Type 8690, 8691, 8692, 8693, 8695, 8696
PX03 (3GD nA/tc – with pilot valve)
PX03 (3GD nA/tc – without pilot valve)
Type 8694
PX03 (3GD nA/tc)
Type 8798
PX03 (3GD nA/tc)
Type 8690 Ex ia IIC/IIIC
4.1.7
Electrical data PX16 (intrinsic safety)
The device Type 8690 in ignition degree of protection intrinsic safety
Ex ia IIC may be connected only to intrinsically safe electric circuits.
Explosion group
Category
Temperature class
-10 – +55 °C
-20 – +60 °C
-10 – +60 °C
-25 – +80 °C
see "Tab. 2"
IIC
ia
T* (see "Tab. 2")

Publicité

loading

Ce manuel est également adapté pour:

Bvs 14 atex e 052 x86908691869286938694 ... Afficher tout