Particularsafetyinstructions
Procedure:
Mount screw, clirclip and fastening element.
Push locking wire through the bore of the transparent cap.
Push locking wire through fastening element and pull it tight.
Tighten screw on the fastening element and clamp locking wire.
Danger!
risk of explosion due to electrostatic discharge.
▶ Ground the metal surface of devices which have a body casing
made of stainless steel (Type 8691, 8692, 8693, 8694, 8695,
8696, 8798).
Use a suitable cable shoe for grounding.
4.3
Adaption set - installation note
Danger!
risk of explosion if incorrect adaption set is used.
▶ Only use suitable adaption set.
The degree of protection required for ignition degree of pro-
tection intrinsic safety "i", is only guaranteed in connection
with suitable adaption sets.
Attachment
Adaption set series
FA03
ELEMENT
FA05
Classic
Tab. 3:
Attachment and adaption set
The order designations for the adaption sets can be found
in the "Order table adaption sets" in the data sheet for the
respective device.
Types 8690, 8691, 8692, 8693, 8694, 8798
Attachment FA03
Fig. 6:
Attachment FA03
English
Attachment fA03
for adaption set of the
ELEMENT series