4.2
installation of locking wire and
grounding of body casing
Danger!
risk of explosion when opening the device.
▶ Open device only when no Ex atmosphere is present.
▶ Prior to start-up, secure the transparent cap against being opened
without tools by using the enclosed locking wire.
Type 8690
Transparent cap
Locking wire
Circlip
Screw
Fastening element
Type 8690
Fig. 4:
Installation locking wire Type 8690
10
English
BVS 14 ATEX E 008 X / E 052 X
Particularsafetyinstructions
Types 8691, 8692, 8693, 8694, 8695, 8696, 8798
Transparent cap
Body casing
Locking wire
Fastening element
for devices with body
casing
Circlip
Screw
Cable shoe
Fig. 5:
Installation locking wire and grounding