INSTALLATION STEP 6

Install the Door Control

Locate the door control within sight of the door at a minimum
height of 5 feet (1.5 m) where small children cannot reach, and
away from all moving parts of the door and door hardware.
1. Strip 7/16" (11 mm) of insulation from one end of the bell
wire. Connect it to the two screw terminals on the back of
the door control by color: white wire to 2 and white/red
wire to 1.
2. Fasten the Lighted Door Control Button securely with
6ABx1" screws. If installing into drywall, drill 5/32" holes
and use the anchors provided.
3. Run the bell wire up the wall and across the ceiling to the
operator. Use staples to secure the wire in several places.
Be careful not to pierce the wire with a staple, creating a
short or open circuit.
4. Operator terminal screws and the antenna are located on
the back panel of the operator. Position the antenna wire as
shown.
5. Connect the bell wire by color to the operator terminal
screws: white to 2 and white/red to 1.
6. Use tacks or staples to permanently attach the entrapment
warning label to the wall near the door control, and the
manual release/safety reverse test in a prominent location
on the inside of the door.
NOTE:
DO NOT connect the power and operate the operator
at this time. The trolley will travel to the full open position, but
will not return to the close position until the sensor beam is
connected and properly aligned. See Safety Reversing Sensor
instructions beginning on page 15.
TO PREVENT THE MOTOR PROTECTOR FROM
TRIPPING, DO NOT EXCEED 8 DOOR
OPERATIONS PER HOUR.
FASTEN LABEL ADJACENT TO DOOR
POUR EMPÊCHER LE DISPOSITIF DE
PROTECTION DU MOTEUR DE SE
DÉCLENCHER, NE PAS DÉPASSER PLUS DE 8
ACTIVATIONS DE LA PORTE PAR HEURE.
PORTE.
132A2112A
2-Conductor
Bell Wire
Lighted Door
Control Terminal
Screws
Lighted
Door Control
Button
12
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing
door control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from
a closing door:
• Install door control within sight of the door, out
of reach of children at a minimum height of 5 feet
(1.5 m), and away from ALL moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote controls.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to
door travel.
• ALWAYS keep the door in sight until completely
closed. NEVER permit anyone to cross the path of a
closing door.
HARDWARE SHOWN ACTUAL SIZE
Screw 6ABx1"
Drywall Anchors
Outside Keylock Accessory Connections
To operator terminal screws: White to 2 and white/red to 1.
2-Conductor
Bell Wire
Back Panel
of Operator
Staples (Not shown)
Operator
Terminal
Screws
Antenna

Publicité