Télécharger Imprimer la page

Selve SE Pro-RC Serie Notice De Réglage page 71

Publicité

Les langues disponibles
  • FR

Les langues disponibles

iveo initial operation/Setting by radio
First press the STOP button and then the UP and DOWN buttons as well. Keep all three
buttons pressed for 9 seconds, in order to start the group separation (wait until the
transmitter control light flashes three times). The motor indicates activation of group
separation by a short run. Then each motor will move randomly for 3 seconds within a
period of about 2 minutes. Within the 3-second time slot, stop the movement of the
motor using the STOP button on the transmitter to be programmed. Then the transmit-
ter is programmed, and the motor has left the group separation mode.
Fuse/Hirschmann plug
3 s
3 s
3 s
Window 1
Window 2
3 s
Transmitter 1
Transmitter 2
If the motors are still moving together, repeat the procedure for the motors affected.
If you did not programm a transmitter through the STOP button and no other trans-
mitter is programmed, you may programm this transmitter again by pressing the UP
and DOWN buttons at the same time and then pressing the PROG button.
7.9. Changing the radio system to commeo
To change the radio system of a motor with iveo transmitters, first set the motor to
service mode and then select the motor using a commeo transmitter by pressing the
SELECT button for 3 seconds. When the motor has been selected, all iveo transmitters
have been re-programmed.
Fuse/Hirschmann plug
3 s
3 s
3 s
Window 3
3 s
3 s
Transmitter 3
3 s
9 s
Every motor moves randomly only for
3 seconds within about 2 minutes.
The motor in question must be
stopped by the selected transmitter
during the movement.