GB Setting of the end positions
4. Setting of the end positions
4.1. Delivery status
In the SELVE delivery status no end positions or transmitters are programmed into
the radio motor! In this state, the motor can be operated in deadman's operation only.
Safety functions such as obstacle detection are deactivated at delivery and will only
become active after both end positions are set.
State at delivery is indicated by a short movement when the radio motor is connected
to power. The SE Pro-RC motor is in automatic setup-mode.
4.2. Mechanic requirements
Operating of the SE Pro-RC motor is possible with normal safety and fixing springs.
Optionally, security springs can also be used (manual setup-mode).
If the motor is supposed to move against the stop in the upper end position, a stable
end stop must be installed!
If the motor is set in automatic setup-mode, a limit must be installed for the lower
switchoff position (e.g. windowsill) for the shutter to run against.
4.3. Setup functions
The end positions setting of a SELVE radio motor is possible via:
• the setting switch for radio motors (item no. 290109),
• any standard switch (in automatic mode),
• any standard commeo or iveo transmitter.
48