iveo initial operation/Setting by radio
7.1. Limit position setting and programming the first transmitter
7.1.1. Automatic setup-mode, deletion and automatic setting of the end positions
 in operation bottom position, top stop/release
When the movement is interrupted twice during operation, the system is in automatic
setup-mode. Motor types SE Pro-RC will automatically find their stop positions. For
this, a motor must first move against the upper stop and then downwards until it
switches off automatically.
Caution!
Only connect the radio motor that you wish to program to the mains. It is not possible
to program more than one motor at the same time.
Setting with
transmitter
or
Auto-Stop top
and bottom,
keep motion button
pressed
1 s
Drive
Connect to power.
Press the UP and DOWN buttons at the transmitter at the
same time. The transmitter is temporarily programmed into
the motor.
The motor moves against the upper stop and stops auto-
matically. The correct direction of rotation assignment has
been made.
Continue to keep the button pressed.
The motor automatically moves downwards after
1–2 seconds. Alternatively move the motor downwards
using the DOWN button.
Note: The motor can be moved upwards and downwards.
As long as the lower end position has not been found, the
downwards moving will be interrupted twice.
The motor will reach the lower limit and stops automati-
cally.
The end positions are now set and the rotation direction
assignment is correct. Perform a test run.
Press the PROG button at the transmitter.
The transmitter is now permanently programmed.