commeo initial operation/Setting by radio
Bit screen and delivery status
SE Pro-RC
Bit position
Receiver function
Status LED = green/1
Status LED = red/0
Adjustable receiver application
A
Receiver application
Venetian blind inside (no sensor loss, wind, rain, frost)
0
0
0
1
Venetian blind outside
0
0
1
Awning/screen inside (no sensor loss, wind, rain, frost)
0
0
1
1
Awning/screen outside
0
1
Business awning (no sun function)
0
0
1
1
Roller shutters (no sensor loss, wind, rain, frost)
0
1
1
Window motor (no sensor function)
0
B
Secondary stations
1
Signal operation, emergency signal above the secondary stations
Deadman mode
0
C Obstacle detection, automatic switching off and clearing off an obstacle
1
Obstacle detection on
Obstacle detection off
0
D Relief function at torque switching off at the upper end limit
1
Release on
Release off
0
Comfort switching off: Drive stops before the upper end limit; every 30
E
ence move against the upper end limit plus relief
1
Comfort switching off is switched on
Comfort switching off is switched off (move against the upper end limit at every move)
0
F
Learning overload protection, when moving to the upper end position
1
Learning overload protection on, system-adjusted overload protection
Learning overload protection off, overload protection with full torque
0
1 2 3 4 5 6 7 8
A
B C D E F
1
1
1 1
0
0
0
63
1
GB
th
move is a refer-