Comfort 400V control unit
Mains switching-on delay [s]
Sensor height
[mm]
2)
Switch lock [s]
3)
Measuring range [mm]
ON1 level [mm]
ON2 level [mm]
4)
OFF1 level [mm]
Alarm level [mm]
Switching-on delay [s]
Post run time [sec.]
5)
200l tank
300l tank
450l tank
Pump mode
(Duo only)
6)
Max. run time
[min]
7)
Max. run occur
8)
min. current [A]
max. current [A]
Air bubbling offset
[mm]
9)
auto SDS [d]
1) A = set, check B = optionally C = Only to be changed by personnel trained by KESSEL
2) Immersion pipe (bottom edge of immersion pipe = bottom edge of tank)
3) Time that passes until the second pump starts up (Duo) and time that passes before a pump can restart.
4) Duo version only
5) Time by which the switching off is delayed in order to vent the immersion pipe of the level sensor.
6) Describes the order in which the pumps switch on and off. It is possible to choose between alternating and fixed order.
7) Maximum run time of the pump continuously at a time. Note pump type S1 and S3.
8) Maximum number of pump starts within 3 minutes. If this value is exceeded, an error message appears (display &
acoustic).
9) Offset required to equalise the pressure produced by a compressor used to cause air bubbling in the system.
32 / 114
Special settings for pump type SPF...
1400
1500
3000
5
5
5
130
130
130
6
6
6
100
100
1000
350
350
350
400
400
400
160
160
160
450
450
450
1
1
1
3
3
3
6
6
5
6
6
6
On
On
On
240
240
240
20
20
20
1
1
1
10
4
6.3
0
0
0
7
7
7
Lifting station/Installation and operating instructions
4500
5500
Setting
range
5
5
0...60
130
130
0...999
6
6
0...30
1000
1000
0...3000
350
350
0...999
400
400
0...999
160
160
0...999
450
450
0...999
1
1
1...10
2
2
1...10
5
3
1...10
5
4
1...10
On
On
Off/On
240
240
40...640
20
20
5...30
1
1
0...5
10
14
0...99
0
0
0...30
7
7
0...14
Comment
1)
B
A
C
B
A
A
A
A
B
A
A
A
B
B
B
A
A
B
B
010-907