Minimum switch-on level
The minimum height for the inlet position (A) is 115 mm.
There must be no drilling below this level, to protect the
pump(s) from running dry.
3.3
Pump SPF
Submersible black water pump with multi-vane impeller
Information / pump type
Weight of
2
Power P1 / P2
Speed
Operating voltage
Rated current
Max. pumping capacity
Max. pumping height
Max. temperature
Pumped medium
Protection rating
Protection class
Motor protection
Connection type
Connecting cable (5 m)
Type of fuse required (Mono)
Type of fuse required (Duo)
Operating mode
(*))
Performance and pumping height
(1)
(2)
(3)
(4)
(5)
2
version for S3 operation 2 kg heavier for S1 operation.
010-907
1400
25 kg
1.6 kW / 1.1 kW
1.4 kW / 1.1 kW
1370 rpm
1415 rpm
230 V; 50 Hz
7.3 A
38 m³/h
40 m³/h
7 m
integrated
coded
3 x 1.5 mm²
C10A
C20A
SPF 1400
SPF 1500
SPF 3000
SPF 4500
SPF 5500
Lifting station/Installation and operating instructions
1500
3000
24 kg
24 kg
3.2 kW / 2.7 kW
2845 rpm
400 V; 50 Hz
2.7 A
5.4 A
47 m³/h
8 m
16 m
40 °C
IP68 (3 mWC/48 h)
I
external
Direct connection
7 x 1.5 mm²
C16A
C16A
C20A
S1 / S3
4500
5500
26 kg
32 kg
4.5 kW / 3.7 kW
5.6kW / 4.8 kW
2850 rpm
2840 rpm
7.5 A
9.1 A
55 m³/h
60 m³/h
20 m
27 m
6 x 1.5 mm
C20A
C20A
C32A
C32A
S3
2
27 / 114