Led 8
Description
Off
During normal operation it indicates that Pole closing is set to the left.
On
During normal operation it indicates that Pole closing is set to the right
Flashes
Programming of functions in progress.
8.4.2 - Flashing light signals
If a flashing light is connected to the FLASH output on the control unit (or the
edge light if the LED flashing light XBA7 is connected, optional accessory), this
emits flashes at intervals of 1 second during execution of a manoeuvre. If faults
Signal
1 flash
second pause
1 flash
2 flashes
second pause
2 flashes
3 flashes
second pause
3 flashes
4 flashes
second pause
4 flashes
5 flashes
second pause
5 flashes
6 flashes
second pause
6 flashes
7 flashes
second pause
7 flashes
8 flashes
second pause
8 flashes
9 flashes
second pause
9 flashes
14 – English
Cause
Bluebus system error
Photocell activated
Activation of Motor Force limiter
STOP input activation
Error on internal parameters in control unit
Maximum limit of manoeuvres per hour exceeded
Error in internal electric circuits
–
Block automation
occur, the flashing light will emit shorter flashes; these are repeated twice, sep-
arated by a 1 second pause. The same signals are also emitted by the courtesy
light and the "Bluebus" led. Table 16 shows the cause and solution for each
type of signal.
TABLE 16
Solution
At the start of the manoeuvre, the devices connected to Bluebus
do not correspond to those recognized during the self-learning
phase. One or more devices may be faulty; check and, if necessa-
ry, replace them. In case of modifications repeat the device self-
learning process (see paragraph 4.5).
At the start of the manoeuvre, one or more photocells do not ena-
ble it; check to see if there are any obstacles.
During the movement, the pole has experienced excessive fric-
tion; identify the cause.
At the start of the manoeuvre or during the movement, the STOP
input was activated; identify the cause.
Wait at least 30 seconds, then try giving a command. If the condi-
tion persists, there may be a serious malfunction and the electro-
nic board must be replaced.
Wait a few minutes until the manoeuvre limiting device falls to
below the maximum limit.
Disconnect all power circuits for a few seconds and then retry a
command; if the condition persists this may indicate a serious fault
with the board or motor wiring. Check and make replacements as
necessary.
Reserved for Nice Technical Assistance
Send the command "Release automation" or control the manoeu-
vre with "High Priority Step Step".