III - SETTING IN OPERATION - INSTALLATION
3.1 Power supply
Attention : Opalys clock has to be powered in TBTS (very low tension) through the power supply
unit delivered.
Setting of the table bracket (if supplied)
(in the 2 notches of the wall bracket).
a. Turn the clock over onto a table (see fig.2).
Unscrew the anti-theft locking screw.
Push in front of the 2 arrows on the wall bracket to unclip it.
Remove the wall bracket / connector cover on the back of the
clock.
b. Connect the mains to the power supply unit.
Remark: the power supply unit can be placed in an embedded
box in compliance with the safety instructions page 25.
c. Fix the wall bracket using the plugs and screws supplied (fixing
points (5)).
161
100
Diag.: 2
Anti-theft locking
screw
Fig.: 3
27