2.2 Electrical installation
The wiring is different depending on the type of clock (single or double sided) and the type of
power supply (low voltage or 100-240V )
2.2.1 Low voltage power supply
Single-sided model:
- Strip the cable from the wall over 10 mm,
- Strip the two wires with a cross-section of 1.5 mm² (maximum) over 5 mm,
- Connect the wires directly to the terminal block on the back of the clock
(at the bottom of the movement) in the power supply terminals, 6-24 V ,
respecting the + / - polarity indicated on the label,
- Affix a cable retainer around the power supply wires.
Remember, conductors on the same circuit must be attached to each
other close to the terminal block to avoid reduced isolation should
one of the terminals become loose.
Double-sided model:
- Route the wiring through the bracket arm,
- Wire the first clock
A
- Wire the second clock
terminals of the first clock
8
as a single-sided clock (see above),
by making a cascade connection to the + / - power supply, 6-24 V
B
.
A
A
A
B
EN
POWER SUPPLY
6-24 V
-
+
1 cm