2.3
Intended use
The KESSEL submersible pump is designed for pumping off wastewater without
sewage in the domestic sector. The water can be soiled by suspended substances
or smaller objects (up to 10 mm in size). During use, the safety instructions, techni-
cal data and mode of operation must be heeded.
L Do not use in a potentially explosive environment (ATEX).
L Only the special version GTF500 Resistant is approved for use with extremely
corrosive wastewater (acid or alkaline).
The product has been designed for the following applications:
• Pumping off smaller water bodies or accumulation of water (mobile use)
• Use in on-site tanks or pump chambers
• As a system pump for lifting stations and pumping stations from the Aqualift
series
2.4
Product description
The grey water submersible pump with multi-vane impeller has a float switch for
level measurement. The connection cable is equipped with an earthed connector.
The intake area of the pump has an intake cage which prevents coarse materials
(>10 mm ø) being drawn in.
The intake cage can be removed during deep extraction.
16
3
4
7
1
8
Fig. [1] Pos. no.
Installation and operating manual
Assemblies and functions
(1)
Intake cage
(2)
Ventilation opening
Float switch
(3)
Mains cable/mains plug
(4)
(5)
Pressure connection
(6)
Hose adapter
(7)
Spiral housing
(8)
Stand (GTF 600)
5
2
6
016-084_02