2.3
Intended use
The chamber system has been designed exclusively to serve as a backwater chamber or for housing various KESSEL
pumping and lifting stations. The excavation pit prerequisites and subsequence backfilling work must comply with the specifi-
cations set out in chapter 4.1 (see "Choose suitable installation location", page 26).
The chamber system must not be used in a potentially explosive environment.
Later extensions to the KESSEL chamber systems must be carried out by KESSEL Factory Customer Services.
All conversions or attachments that are carried out without the express and written permission of the manufacturer, the use
of non-genuine spare parts and repairs carried out by companies or persons not approved by the manufacturer will lead to a
loss of warranty.
The stability of the product is only guaranteed for its own weight, transport and the installation described in accordance
with intended use (e.g. load class, road construction, reinforcement drawing, structural use in accordance with approval).
Additional loads from single or strip footings or other external impacts must be avoided. Special measures may have to be
taken if these are to be expected.
2.4
Product description
The chamber system has a modular design and is suitable for housing various pumping and lifting stations.
Each spacer ring (with intermediate section and taper) is fitted with at least one access step. The spacer rings are fitted
together without tools.
The upper sections are continuously height-adjustable and can be fitted with different cover plates.
Waterproof requirements can be fulfilled by installing a sealing sheet.
010-701
Engineering chamber LW 1000 /
Installation and operating instructions
21 / 100