Kessel GTF 500 Notice D'utilisation D'origine page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
Setting up the pressure connection (A - connection PVC pipe)
B
A
▶ Route the pressure pipe (via backwater loop) to the pump sump.
▶ Attach the pressure pipe to the connecting socket.
Setting up the pressure connection (B - mobile use)
▶ Remove the connecting socket (two screws).
▶ Attach the hose adapter including seal using the same screws.
▶ Pull the fixing clamp over the end of the pressure hose.
▶ Push the pressure hose onto the hose adapter.
▶ Tighten the fixing clamp hand-tight in a suitable position.
D
C
Setting up the pressure connection (C/D/E – use as system pump)
▶ Remove the connecting socket (two screws).
▶ Mount the adapter for one-handed closure/ riser pipe/ flap housing.
▶ Place the pump.
▶ Lock one-handed closure (or upper hose clamp).
E
Establishing the mains connection/commissioning
▶ Plug in the mains plug.
✓ Pump starts up automatically (with corresponding level).
▶ Check whether the pressure hose is still firmly connected after the pump has
started running.
▶ Carry out functional check
(
➲ Chap. „Maintenance").
✓ Commissioning of the submersible pump is completed.