4.3 Error Codes
The following tables contain possible errors to be encountered and their solutions.
Error Code
Thermal
E01
Protection
(Primary)
Low Mains
E02
Voltage
High Mains
E03
Voltage
Temperature
E05
Sensor Failure
Water Cooling
E06
Unit Error
High Output
E07
Voltage
High Primary
E09
Current
E12
VRD Error
Communication
E14
Thermal
E19
Protection
(Secondary)
www.magmaweld.com
Error
The machine's run time duty cycle
rate may have been exceeded
Fan may not be operating
The air inlet and outlet ducts may
have been blocked
The machine operating environment
can be extremely hot or lack of air
Mains voltage may have decreased
Mains voltage may have increased
Temperature sensor may have failed
or there may be an electrical
connection problem
There may be an error in the water
cooling unit
There may be electrical problems in
the machine
Low mains voltage may be present
There may be electrical problems in
the machine
There may be electrical problems in
Error
the machine
The machine's run time duty cycle
rate may have been exceeded
Wait for a while to allow the machine
Reason
to cool down. If the failure
disappears, try to run the machine at
lower amperage values
Visually inspect the fan for proper
operation. Please contact the
authorized service if it does not
operate
Open the air ducts
Ensure that the machine is placed in
an area where it can work operate
comfortably
Check the mains connection cables
and voltage. Make sure that the
correct voltage input is provided. If
the mains voltage is normal, contact
the authorized service
Check the mains connection cables
and voltage. Make sure that the
correct voltage input is provided. If
the mains voltage is normal, contact
the authorized service
Contact the authorized service
Check water cooling unit connector
and torch inlets/outlets. Make sure
there is water circulation.
If the problem continues, contact the
authorized service
Contact the authorized service
Contact the authorized service
Contact the authorized service
Contact the authorized service
Wait for a while to allow the machine
to cool down. If the failure
disappears, try to run the machine at
lower cycle rates
Maintenance and Service
Solution
USER MANUAL