Error Codes - Magmaweld MONOTIG 220ip Manuel D'utilisation

Masquer les pouces Voir aussi pour MONOTIG 220ip:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MONOTIG 220ip - MONOTIG 220ip AC/DC

4.3 Error Codes

The following tables contain possible errors to be encountered and their solutions.
Error Code
Thermal Protection
E01
(Primary)
Low Mains
E02
Voltage
High Mains
E03
Voltage
Temperature
E05
Sensor Failure
High Output
E07
Voltage
High Primary
E09
Current
E12
VRD Error
Communication
E14
Thermal Protection
E19
(Secondary)
www.magmaweld.com
Error
• The machine's run time duty cycle rate may
have been exceeded
• Fan may not be operating
• The air inlet and outlet ducts may have been
blocked
• The machine operating environment can be
extremely hot or lack of air
• Mains voltage may have decreased
• Mains voltage may have increased
• Temperature sensor may have failed or there
may be an electrical connection problem
• There may be electrical problems in the
machine
• Low mains voltage may be present
• There may be electrical problems in the
machine
• There may be electrical problems in the
Error
machine
• The machine's run time duty cycle rate may
have been exceeded
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Reason
• Wait for a while to allow the machine to cool
• Visually inspect the fan for proper operation.
• Open the air ducts
• Ensure that the machine is placed in an area
• Check the mains connection cables and
• Check the mains connection cables and
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Contact the authorized service
• Wait for a while to allow the machine to cool
Maintenance and Service
Solution
down. If the failure disappears, try to run the
machine at lower amperage values
Please contact the authorized service if it
does not operate
where it can work operate comfortably
voltage. Make sure that the correct voltage
input is provided. If the mains voltage is
normal, contact the authorized service
voltage. Make sure that the correct voltage
input is provided. If the mains voltage is
normal, contact the authorized service
down. If the failure disappears, try to run the
machine at lower cycle rates
29
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Monotig 220ip ac/dc

Table des Matières