14
Technical Information
Temperature (C°)
Duty Cycle
EN
As defined in the standard EN 60974-1, the duty cycle rate includes a time period of 10 minutes.
6 min.
For example, if a machine specified as 250A at %60 is to be operated at 250A, the machine can weld without
interruption in the first 6 minutes of the 10 minutes period (zone 1). However, the following 4 minutes
should be kept idle for the machine cool down (zone 2).
1.4 Technical Data
Mains Voltage (1 phase - 50-60 Hz)
TECHNICAL DATA
Rated Power (MMA)
Rated Power (TIG)
Welding Current Range
Rated Welding Current
Open Circuit Voltage
Welding Electrode Diameter Range
Tungsten Electrode Diameter Range
Dimensions (LxWxH)
Protection Class
Mains Voltage (1 phase - 50-60 Hz)
TECHNICAL DATA
Current Absorbed from Mains (50 Hz)
Current Absorbed from Mains (60 Hz)
Cooling Capacity
Dimensions (LxWxH)
Protection Class
USER MANUAL
4 min.
6 min.
Weight
Weight
monoTIG 220ip / 220ipw / 220ip AC-DC / 220ipw AC-DC
4 min.
monoTIG 220ip
V
230
UNIT
monoTIG 220ipw
kVA
9.2 (%15)
kVA
8.05 (%20)
ADC
3-220
ADC
220 (%20)
VDC
87
mm
2.00 - 5.00
mm
1.00 - 2.40
mm
474 x 221 x 395
kg
15.5
IP21
V
230
UNIT
CSP 45
A
0.65
A
0.71
kW
0.75
mm
510,5 x 221,5 x 246,7
kg
11,4
IP21S
6 min.
4 min.
monoTIG 220ip AC/DC
monoTIG 220ipw AC/DC
9.2 (%15)
8.05 (%20)
3-220
220 (%20)
2.00 - 5.00
1.00 - 2.40
529 x 221 x 395
CSP 45 AC/DC
569,5 x 221,5 x 246,7
IP21S
www.magmaweld.com
Time (min.)
230
87
16.5
IP21
230
0.65
0.71
0.75
12,2