Maintenance and Service
4.4 Error Codes
EN
Error Code
E01
E02
E03
E04
E05
E06
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Error
Communication
• There may be problems at different
Error
points in the machine
• The machine's run time rate may have
been exceeded
• Fan may not be operating
Thermal
Protection
• The air inlet and outlet ducts may
have been blocked
• The machine operating environment
can be extremely hot or lack of air
• The machine may have been
overloaded
Overcurrent
Failure
• There may be problems at different
points in the machine
Low mains
• Mains voltage may have decreased
voltage
Temperature
• Temperature sensor may have failed
Sensor
or there may be an electrical
Reading Failure
connection problem
High mains
• Mains voltage may have increased
voltage
Cause
• Contact the authorized service
• Wait for a while to allow the machine
• Visually inspect the fan for proper
• Open the air ducts
• Ensure that the machine is placed
• Contact the authorized service
• Contact the authorized service
• Check the mains connection cables
• Contact the authorized service
• Check the mains connection cables
SMART SERIES / SMART SERİSİ
Solution
to cool down. If the failure
disappears, try to run the machine at
lower amperage values
operation. Please contact the
authorized service if it does not
operate
in an area where it can work operate
comfortably
and voltage. Make sure that the
correct voltage input is provided. If
the mains voltage is normal, contact
the authorized service
and voltage. Make sure that the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service