This scale is a combination of sound and proven mechanical design, with today's most advanced electronics
to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.
•
Superb Quality – strictly in accordance with European CE directives.
•
Great Safety – Auto-Off function, Standby function
•
Strong Reliability – Cutting-edge technology, quality integrated circuit for high
performance and long time stability.
•
Broad Applicability – Popular and applicable in storage, textile, metallurgy industry, and
so forth.
General safety information for the use of our scale
For good performance and precise measurement, be careful with daily operation and maintenance.
•
Do NOT overload scale. This will damage load cell and void warranty.
•
Do NOT leave load hung on the scale for long. This will decrease scale's accuracy and shorten load
cell's life.
•
Inspect shackle and hook before using. Check clips, pins and screws regularly.
•
Check battery frequently. When scale runs out of power, charge battery with its dedicated charger or
replace it with a full one.
•
Rotate load rather than scale if needed.
•
Do NOT use scale under thunder or rain.
•
Hang scale on shelf in dry and well-ventilated room. Do NOT place scale on the ground directly.
EN
•
Do NOT attempt to repair scale yourself. Contact your local representative.
BEFORE FIRST USE
Upon receipt of the goods, check the packaging for integrity and open it. If the packaging is damaged, please
contact your transport company and distributor within 3 days, and document the damages as detailed as
possible. Do not turn the package upside down! When transporting the package, please ensure that it is kept
horizontal and stable. The various items used for packaging (cardboard, plastic straps, polyurethane foam)
should be conserved, so that the device can be sent back to the service centre in the best condition in case
of a problem!
REV. V 2016
USER'S GUIDE
16
SPECIFICATIONS
Model
Accuracy Class
Tare Range
Zero Range
Stable Time
Overload
Safety Load
Ultimate Load
Battery
Op. Temp.
Op. Humidity
Display
Max. Capacity
Min. Capacity
Resolution
DISPLAY AND KEYS
Main display
Key
Name
Function
On/Off
Press for 1sec to power-on or power-off the scale. Single pressing
Tare
Hold
lock/unlock, confirmation/move further. Longer pressing: change
REV. V 2016
SBS-KW-1000/10G
Class III Equivalent to OIML R76
100% F.S.
±4% F.S.
≤10 sec
100% F.S. + 9e
120% F.S.
400 % F.S.
3 * AA 1.5V
-10°C ~ +40°C
20°C ≤90%
22 mm / 11mm – LCD
1000 kg
10 kg
0.5 kg
will cause exit and return to weighing mode.
Tare. Press for tare. Longer pressing: zero.
the units.
17