Battery And Charging - Steinberg Systems SBS-KW- 1TE Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21

5. BATTERY AND CHARGING

When there is low power in the battery, specifically when the voltage is less than 5.4V,
the scale will alarm by displaying LB. The scale need to be charged now.
When the battery is less than 5.25V, the scale will go into sleeping mode. It will repeat
displaying U5.2 and the buzzer will give out alarm sound instantly. Then the scale must
be charged.
The scale will power off automatically after displaying LB for 20 times without charging.
It can be charged no matter the scale is switched off or during working. It takes around
8 hours to fully charge the battery. After a full charge the scale will automatically stop
charging and voltage will be displayed when turn on the scale.
6. PRECAUTIONS
Electronic crane scale is precise measuring instrument, safety precautions should be
always followed including the following:
6.1
Do not exceed the maximum weight capacity
6.2
Lift and descend goods vertically and dragging goods is forbidden.
6.3
Please check whether the screws, bolt and circlip are loosened or
disengaged before use to ensure safety and accurate measurement
EN
6.4
Avoid any intensive impact and long rain catching. When using outdoor,
please turn off the crane scale if there is a thunder.
6.5
When working under high temperature, please buy high-temperature crane
scale. The distance between the bottom of crane scale and the hanged
heating source should be more than 1600mm. The temperature for weighing
article should not be higher than 180°C and long time working under high
temperature is forbidden
6.6
Do not overload to avoid the damage of sensor. When the weight reaches
120%F.S, the system will give alarm sound. Please remove the overload
weight immediately.
34
6.7
Charge battery generally per month even when not in use to avoid battery
damage caused by self-discharge.
7. SIMPLE FAULTY JUDGE
Description
Judgment
No react after power on
Dead battery
The plug on battery get
loose
It is not"0.0" without load Short warm-up time after
power on
The scale is lying on
group when using
Power off automatically
Extremely low voltage
after power on
battery, Auto-power off
voltage 5.4V
Failure in charging
Damaged battery
Poor contact between the
charging plug and socket
,or damaged plug/socket
Unstable weight value
Sensitive load cell or bad
load cell
Water inside scale or
damp scale
Charging lamp not light up damaged adaptor
contact defective of the
adaptor
Solution
Replace a new battery
Fix the loosen plug
Warm-up for 15 minutes
Please hang up the scale
vertically
Please charge the battery
immediately
Replace the battery
replace the charging plug
or socket
replace a new load cell
Please stock the scale in a
dry place
replace a new adaptor
check the socket and
replug in