TROUBLE SHOOTING, TECHNICAL DATA
Error message
CN099:
Recov escape
CN104:
Battery over heating
CN110:
Blade motor over
heating
CN119:
R-Bumper deflected
CN120:
L-Bumper deflected
CN128:
Recov Im- possible
CN129:
Blocked WL
CN130:
Blocked WR
Data evoCUT 4.0
Length / width / height in mm
Weight in kg
Mowing system
Cutting blade motor rpm
Cutting heights in mm
Cutting height adjustment 7-stage
Cutting width in mm
Max. lawn to be mown in m 2
Max. slope of the lawn in %
Distance from boundary cable to boundary line (wall/hedge) in cm
Base station/transformer data
Base station connection voltage
Secondary voltage/current/power
Noise emissions
Volume measured in dB(A) / volume guaranteed in dB(A)
Battery
Voltage V
Capacity Ah
Energy Wh
ENGLISH 16
Possible cause
Automatic fault rectification not
possible.
Battery overheating – battery
temperature above 60 °C, not
discharging possible
Overheated mowing motor,
temperature > 80 °C
Automatic lawnmower has
encountered an obstacle and
cannot move clear for safety
reasons, e.g. collisions close to
base station.
Obstacle encountered or outside
loop -> reversing not possible,
automatic lawnmower cannot free
itself.
Left wheel motor blocked.
Right wheel motor blocked.

19. TECHNICAL DATA

Solution
Rectify fault manually.
Emergency switch-off by monitoring
electronic control unit. Do not place
automatic lawnmower on base station.
Switch off automatic lawnmower and let
battery cool down.
Switch off automatic lawnmower and let
it cool down. If this reoccurs, have
automatic lawnmower checked by a
SOLO service partner.
Remove obstacle and acknowledge fault
message.
Remove obstacle, check cover deflection.
Remove blockage.
Remove blockage.
600 / 490 / 245
approx. 11.5
Electric with 2 cutting blades
30 - 60
5 mm Per stage
approx. 2.000
approx. 15
230 V 16 A 50 HZ
27 V AC / 2,2 A / 60 VA
63 / 65
106 - 109
3400
320
35
25,2
4,3