4.3

Standard setting values

NOTE
Valve type
6021 DN 1.6
6022 DN 2
6022 DN 4
6023 DN 4
6023 DN 6
6223 DN10
6223 DN13
6223 DN 20
2821 DN 1,6
2832 DN 2
2832 DN 4
2832 DN 4 EEx *
2834 DN 4
2834 DN 6
2836 DN 10
2836 DN 12
* pre-pressure 0,5 bar, pressure drop 0,5 bar
Connection for the monitor signal:
Cable plug electronics type 1094-PMR
Normschienenelektronik Typ 1094-PHR
22
With a pre-pressure of p
(∆p = 1 bar), we recommend the following flow settings as
standard values, which you can check on the monitor:
Monitor signal in mV** at
Start of opening of valve
( I 1 / Potentiometer R 1 )
135
260
210
420
340
90
80
200
125
285
175
90
440
400
480
430
= 1 bar and a flow free of back-pressure
1
Full of opening of valve
( I 2 / Potentiometer R 2 )
1100
1100
** 1 mV monitor signal = 1 mA coil current
Terminal 5
Terminal 3
Terminal AN 2-5
Terminal AN 1-3
165
300
300
530
530
300
330
530
185
350
350
200
650
650
Monitor signal
Earth
Monitor signal
Earth
Type 1094