English
4. Verify on the display that the unit has reached the proper
setpoint temperature, and load the shelf with pans that
contain pre-chilled food product.
• For HCSBF units, always use a food pan on the
hardcoat aluminum surface. Do not place food directly
onto surface.
• Stir thick food items frequently to keep food chilled
uniformly.
WARNING
Hatco Corporation is not responsible for actual food
product serving temperature. It is the responsibility of the
user to ensure that food product is held and served at a
safe temperature.
Shutdown
1. move the Power Switch to the center "O" (off) position. The
digital temperature controller and condensing unit will shut
off.
2. Perform
the
"Daily
maINTENaNCE section of this manual.
Changing the Setpoint Temperature
Use the following procedure to change the setpoint temperature
on both digital temperature controllers. The setpoint
temperature range for the COLD controller is 10°F (-12°C) to
50°F (10°C). The setpoint temperature range for the HOT
controller is 65°F (18°C) to 192°F (89°C).
NOTE: Changes to the setpoint temperature should be made
in small increments (1 to 2 degrees). Wait at least two
hours after a change in setpoint temperature before
checking for the desired result.
1. Press and hold the
display flashes the current setpoint temperature.
2. Press the
or
setpoint temperature. If no key is pressed within 60 seconds,
the display will revert to normal operation and the current
temperature of the unit will be shown on the display.
3. Press the
key to lock in the new setpoint
temperature. The display will revert to show the current
temperature of the unit.
Display
Unit
"Active"
Symbol
Digital Temperature Controller
Form No. HCSm-0416
Cleaning"
procedure
key for one second until the
key to increase or decrease the
SET
Up Arrow/
Standby Key
Key
Down Arrow/
Defrost Key
Setting the Auto-Defrost Cycle (COLD Mode)
The COLD digital temperature controller is programmed at the
factory with the auto-defrost cycle deactivated. Use the
following procedure to activate the auto-defrost cycle if ambient
or operational conditions require the unit to defrost occasionally.
When the unit is in a defrost cycle,
display.
1. Press and hold the
programming mode. "PS" (password) will appear on the
display.
2. Press the
the display.
3. Press the
on the display, then press the
4. Use the
programmable parameters until "dI" (defrost interval)
appears on the display.
in
the
5. Press the
defrost cycles will be shown on the display. For new units,
this value will be "0".
6. Press the
the desired number of hours between defrost cycles. See
below for examples of how the defrost cycle(s) operate:
"0" = auto-defrost is deactivated
"1" = unit will defrost every hour
"4" = unit will defrost every four hours (recommended)
"12" = unit will defrost every twelve hours
If no key is pressed within 60 seconds, the display will
revert to normal operation and the current temperature of
the unit will be shown on the display.
7. Press the
8. Press and hold the
programming mode. The display will revert to show the
current temperature of the unit.
NOTE: Once the unit begins a defrost cycle, defrosting cannot
be cancelled. Defrosting lasts approximately 30 minutes.
17
OPERATION
will appear on the
key for three seconds to access
key again. a numeric value will appear on
or
key until the number "22" appears
key.
or
key to scroll through the
key to select "dI". The current number of
or
key within 60 seconds to scroll to
key to lock in the new defrost cycle setting.
key for three seconds to exit