INSTALLATION
5. Carefully lower the condensing unit followed by the hot/cold
shelf into the countertop cutout. This step requires two or
more people.
• The condensing unit must go into the cutout first and be
fastened to a level, stable surface within 4' (1219 mm)
of the connections on the bottom of the hot/cold shelf.
Refer to the SPECIFICaTIONS section for installation
dimensions.
• The hot/cold shelf rests on top of the four leveling bolts,
which are part of the mounting bracket assembly
installed at each corner of the countertop cutout.
6. adjust the leveling bolts underneath each corner of the unit
so that the shelf is flush or slightly below the countertop
surface.
7. Tighten the lock nut on each leveling bolt to secure the
position.
8. apply a bead of National Sanitation Foundation (NSF)-
approved silicone sealant in the gap between the
countertop and the hot/cold shelf. To apply a clean,
consistent sealant bead:
a. make sure the shelf is centered in the countertop cutout.
b. Install masking tape on each side of the gap to define
the edge of the sealant.
c. Carefully apply sealant into the gap.
d. Quickly smooth the sealant surface.
e. Carefully remove the masking tape before the sealant
dries.
NOTE: The silicone sealant must be rated for use at
temperatures between -10°F (-23°C) and 250°F
(121°C).
DO NOT tip unit/mounting surface after final installation.
Unit is free-floating and could fall out if tipped—for
permanent, horizontal installations only.
9. Install the control panel in the desired location, if installing
remotely.
• The control panel can be installed remotely within 4'
(1219 mm) of the condensing unit. Refer to the
"Installing the Control Panel Remotely" procedure in this
section.
10. Clean the hot/cold shelf surface thoroughly in preparation
for initial operation. Refer to the maINTENaNCE section
for proper cleaning procedures.
11. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICaTIONS section for details.
CAUTION
Installing the Control Enclosure Remotely
Use the following procedure to install the control enclosure
remotely within 4' (1219 mm) of the condensing unit.
Control enclosure must be mounted in a vertical surface.
Mounting control enclosure in a horizontal surface may
result in the collection of liquids and lead to electric shock.
1. Remove the six trim cover screws from the control
enclosure, and remove the trim cover.
2. Position the control enclosure into the cutout opening
through the backside.
3. Fasten the control enclosure to the vertical surface using
four screws (not supplied).
4. Reinstall the trim cover on the control enclosure and secure
in position using the six trim cover screws. Seal the trim
cover to the mounting surface with silicone adhesive.
13-1/16"
(332 mm)
13-3/8"
(340 mm)
Control Enclosure Cutout Dimensions
NOTE: Make sure the width of the control enclosure cutout
does not exceed the above dimension.
14
English
WARNING
5-5/8"
(143 mm)
Form No. HCSm-0416
1-1/16"
(27 mm)
3-1/2"
(89 mm)