Functional principle
The electronic knob cylinder C100 V3 half-cylinder does not have an interior door
knob. The exterior door knob is activated at the electronic cylinder C100 after a
positive authorisation.
The electronic knob cylinder C100 V3 is connected through a hub to an online EAC
system. The authorisation decision sent to the knob cylinder is based on the data
stored on the server.
The Firmware can be updated and the electronic C100 V3 Knauf cylinder can be
configured via the USB interface..
ID media for emergency authorisations
If the connection to the online EAC system fails, the electronic knob cylinder
C100 V3 can be opened with one of ten ID media for emergency authorisation.
The outside door knob can then be released directly by knob electronics.