Automatic Jump Start Systems and Selector Switches
Automatic jump start systems and selector switches tie the negatives of the connected batteries together. Connecting these systems to the
"High Side" Battery or "Middle" Battery in the diagrams below and will cause significant damage to your trolling motor and electronics.
The only trolling motor battery that is safe to connect to one of these systems is the "Low Side" Battery.
CONNECTING THE BATTERIES
12 Volt Systems
1.
Make sure that the motor is switched off (speed selector on "OFF" or "0").
2.
Connect positive ( + ) red lead to positive ( + ) battery terminal.
3.
Connect negative ( – ) black lead to negative ( – ) battery terminal.
For safety reasons do not switch the motor on until the propeller is in the water. If installing a leadwire plug, observe proper polarity
and follow instructions in your boat owner's manual.
©2018 Johnson Outdoors Marine Electronics, Inc.
WARNING
CONNECTING THE BATTERIES
minnkotamotors.com | 15