CAUTION

Risk of injury

Physical injury caused by the start of the wire.
• Keep the process-side drive away from the body.
1 Connect the cable assembly to the interface (6) and lift off the protection cap. Connect the control leads to the master
feeder MF1.
2 Rotate the eccentric bolt (3) and remove it upwards.
3 Open the rocker arm (8).
4 Press the inching trigger (7) until wire (5) becomes visible. Introduce the wire (5) into the wire guide speed sensor (2)
(and on retraction into the torch).
5 Feed it through the wire guide speed sensor (2) using the inching trigger (7). When doing so, open the pressure
lever (1) for the wire actual value encoder (9).
The contact pressure of the wire actual value encoder (9) is pre-set for wires from 0.8 to 1.0 mm.
6 Close the rocker arm (8) and insert the eccentric bolt (3).
7 Press the inching trigger (7) until wire (5) emerges from the torch neck.
6.3 Control lead pin assignment
Fig. 7
Control lead pin assignment