MF1
Risk of injury
Bodily harm caused by the beginning of the wire.
• Keep process-side drive away from the body.
1 Connect the cable assembly to the interface (6) and lift off the protection cap. Connect the control leads
to the frontdrive MF1.
2 Rotate the eccentric bolt (3) and remove it upwards.
3 Open the pressure rocker (8).
4 Press the inching trigger (7) until wire (5) becomes visible.
5 Introduce the wire (5) into the wire guide speed sensor (2) (and on retraction into the torch) and feed it
through the wire guide speed sensor (2) using the inching trigger (7). When doing so, open the pressure
lever (1) for the wire actual value encoder (9).
The contact pressure of the wire actual value encoder (9) is pre-set for wires from 0.8 to 1.2 mm.
6 Close the pressure rocker (8) and insert the eccentric bolt (3).
7 Press the inching trigger (7) until wire (5) emerges from the torch neck.
6.3 Connector assignment of control lead
Fig. 7
CAUTION
Connector assignment of control lead
6 Putting into operation
EN - 13