Technicaldata
output is set to zero.
5.3.

Version available

The following version of the electrolyte monitoring is available. This
reference includes the ultrasonic module and a 5-meter long cable
including a 5-pin M12 plug.
Supply voltage Output
12-30 VDC
PNP
Type 8201
Electrical
Ordering code
connection
M12, 5-pin male
561533
fixed connector
English
6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature: +5 to +60°C (operating)
Protection rating:
IP67
6.2.
conformity to standards and
directives
The conformity of the device to the EC directives is fulfilled by the
following standards:
• EMC: EN 61000-4-3, EN 61000-4-4, EN 61000-4-6, EN 55011
6.3.

General technical data

6.3.1.

mechanical data

component
material
Sensor/Cover
POM
Ultrasonic Cell
PPMA
Mold of the plug
PUR
O-ring
FKM
9