Burkert 2301 Guide Rapide page 13

Masquer les pouces Voir aussi pour 2301:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

8.3
installation
Warning!
risk of injury from improper installation!
Assembly with unsuitable tools or non-observance of the tight-
ening torque is dangerous as the device may be damaged.
▶ For installation use an open-end wrench, never a pipe wrench.
▶ Observe the tightening torque (see "Tab. 5").
dirt trap for devices with authorisation in accordance with din
en 161
In accordance with DIN EN 161 "Automatic shut-off valves for gas
burners and gas appliances" a dirt trap must be connected upstream
of the valve and prevent the insertion of a 1 mm plug gauge.
8.3.1 installation of the valve body
Welded bodies
Weld valve body in pipeline system.
other body versions
Connect body to pipeline.
8.3.2 install actuator (welded body)
Fig. 4:
Graphite seal
12
Graphite seal
english
Type 2301
Technical data
Check the graphite seal and if required, replace it.
Warning!
danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen appli-
cations there is a risk of an explosion!
▶ In specific applications, e.g. oxygen or analysis applications, use
appropriately authorized lubricants only.
Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).
note!
damage to the seat seal or the seat contour!
▶ When installing the actuator, ensure that the valve is in open
position.
Control function A pressurize the pilot air port 1 (see „Fig. 5")
with compressed air (5 bar): valve opens.
Screw actuator into the valve body. Observe tightening torque
(see "Tab. 5").