Performax Iq Easy Ex Speed Connection To The Ex Status Module - ITW SIMCO ION Performax IQ Easy Ex Mode D'emploi

Anti-static bar
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.8.2 Performax IQ Easy Ex Speed connection to the Ex Status module

Mount the Status Module at a place outside the EX-Zone.
Image 5.8.2.1: Prepare connection Status Module
Use 2 bolts or screws of a max. ⦰ 4 mm. Take into account 15 cm of space for the cable
connection from the EX anti-static bar on one side, and the cable with connector on the other
side. Also note that the LED next to the connector should be visible in order to view the status of
the anti-static bar.
For an EX-bar with protective hose:
- When needed: cut the 5-wire cable to the desired length.
- Cut the protective hose on the needed length. This is the cable length - 32mm (see image
5.8.2.3).
- Push a yellow seal on the protective hose on the bar side. (see image 5.8.2.4).
- Run the cable through the protective hose with the yellow seal at the bar side.
- Push the protective hose into the fitting of the ionization bar until the yellow seal is no longer
visible (see image 5.8.2.5).
- Insert the grey clip into the fitting with the slot facing the outside, so it can be removed with a
screw driver if required (see image 5.8.2.6).
- Push a yellow seal on the protective hose on the status module side
- When needed: strip the cable according picture 5.8.2.7 mount proper ferrules (within
shipment) to the end of the wires.
- Screw the fitting into the Status Module and run the stripped cable through the fitting.
- Push the protective hose into the fitting of the ionization bar until the yellow seal is no longer
visible (see image 5.8.2.8).
- Insert the grey clip into the fitting with the slot facing the outside, so it can be removed with a
screwdriver if required.
- Connect the cable to the pcb of the Status Module.
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
Remove the cover of
the Status module
and remove the
blind plug.
Image 5.8.2.2: Sizes of fixing holes Status Module
LED