4 Technical specifications

Power Requirements
Supply Voltage
Primary Fuse
Current consumption
Connection
Power supply
Max. cable resistance per wire
Max. total cable length Standard
Simco 5x0,34 mm
2
&
M12 Male-Female cable
Type power supply
Input
Remote on/off
Activation time
Output
Output voltage emitters
Current per emitter to earth
High voltage OK (HV OK)
Environment
Usage
Ex environment (See chapter 3)
Protection class
Ambient temperature
Max. Temperature enclosure
Material speed
Working distance
Local signaling
2-Color LED
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
24 V DC nominal
0,5 AT, Type: 70-007-65/0.5A, Siba
This fuse has a rupturing capacity of min 1500A (breaking
capacity).
This fuse is present in the delivered Ex Status Module by Simco-
Ion.
Max. 0,4 A DC
2
Cable 5 x 0,34 mm
24V DC ± 2%
24V DC ± 5%
3,125Ω
2,25Ω
62,5m
45m
100-240 V AC
Manager IQ Easy
100-240 V AC
Extension IQ Easy
10 – 30 V DC nominal (Ri >10k)
30 ms
Max. 9 kV positive and negative
Max. 50 µA
Supply voltage -1 V, max. 50 mA
Industrial, indoor usage
ATEX
II 2 GD
Ex mb IIB T4 Gb
Ex mb IIIB T135°C Db
IP66
0 - 40°C
135°C
Performax IQ Easy Ex
Performax IQ Easy Ex Speed
Performax IQ Easy Ex
Performax IQ Easy Ex Speed
Continual:
Green
In use
Red
Overloaded
See chapter 7 for more info
24V DC ± 10%
0,75Ω
15m
IECEx BAS 17.0095X
Ex mb sb IIB T4 Gb
Ex mb sb IIIB T135°C Db
0 – 500 m/min
>500 m/min
100 - 300 mm
50 – 300 mm
Blinking:
Stand-by
No communication
70