6.4.2 Operation mode CLFB (Closed Loop FeedBack) with Sensor IQ Easy

First the Sensor IQ Easy must be paired with the Performax Ionisation bar.
Go with the following page
-
Click Paired sensor
- Select the IQ Easy sensor which will provide
the measurement values for the anti-static bar
- With several sensor segments in operation, an individual sensor segment can be switched
off. This may be necessary in case you are using a smaller film and hence a segment of the
sensor will be outside of the area of the film. The anti-static bar will then calculate using the
average measurement values of the active (enabled) segments
- To disable a segment, click
- Select the segments to be disabled
- Confirm selection with
Go with the previous page
parameter Operation mode
- Select CLFB
The sensor bar should now be connected to the
Performax IQ Easy Ex bar.
The anti-static bar will now use the average (avg)
of the enabled segments to regulate ionization.
6.5 Anti-static bar Standby & Active and Autorun setting.
By default, the bar will become active once the Manager has gathered all the information,
because the autorun parameter has been set to yes.
On each tab, you can set the device to Standby
The status is indicated in the left upper corner by means of a color behind the
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
symbol to the parameter Paired sensor.
Enabled segments.
symbol to the
or active mode
symbol: