Image 5.8.2.9: Connection wiring Performax Easy EX Speed with the Status Module
Push the protective hose into the Status Module until the yellow
seal is no longer visible (1). Then insert the grey clip in the fitting
with the slot facing the outside (2),
so it can be removed with a screw driver if required.
Then replace the cover and fasten with the screws.
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
Connect the cable according to the table below:
Colour:
Brown
White
Blue
Black
Yellow/green or grey
Image 5.8.2.10: Fixing a protective hose to the fitting
Connection: Number:
+ 24 V
1
A
2
0 V
3
B
4
Earth
5