Connection; Earthing - ITW SIMCO ThunderION Notice D'utilisation

La barre permet de neutraliser la charge électrostatique des feuilles, bandes et autres matériaux plats
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 Fit the anti-static bar with the emitters towards the material to be discharged.
Use the supplied mounting materials, see fig. 1 and 3.
 Mount the bar such that the emitters are at a distance of at least 50 mm from electrically con-
ductive machine parts. This prevents spark-over.
If this distance cannot be achieved, an optional side panel can be placed,
item number: 7510900010.
Only use the side panel if absolutely necessary, as the bar operates less effectively when the
side panel is fitted.

4.4. Connection

4.4.1. Earthing

For personal protection and to ensure proper functioning, the following earth connections must
both be made:
 the fitted (yellow/green) earth wire to an earthed part of the machine.
 the 0 V of the power cable on the supply side to earth.
In the power units supplied by SIMCO (Nederland) B.V., the internal 0 V is connected to the
safety earth. Make sure that the power cable of the power units is earthed correctly.
ThunderION_UM_9752160010_NL_D_GB_F_V2_2
Figure 3
GB
33