6.8 Datalogging (de-)activation.

If required, the Manager can log data regarding the operation of the bar.
To (de)activate this data logging, the parameter Datalogging has to be changed.
For detailed information on data logging, please refer to the manual Manager IQ Easy
- [
(n)x

6.9 Clean bar warning level setup (expert mode)

The IQ Easy Ex bar should after calibration (6.3) continuously monitor the effectiveness of the
bar. Should the effectiveness fall below the set Clean bar warning level due to contamination,
buildup or other causes, a warning (LED on the bar blinking red / green and a orange icon will
be generated on the Manager).
By default, this level is set to 50 %, but it can be set to a different value in specific cases
- [
(n)x
required value and confirm with

7 Checking the Functionality

7.1 Checking neutralization

To measure the efficiency of the anti-static bar, a field strength meter can be used, which is
suitable for use in hazardous areas.
Connect the field strength meter with the grounding, keep a minimum distance of 30 cm from
the anti-static bar.
Measure the static charge of the material before and after it has passed the anti-static bar.
The measured charge must have minimized after the material has passed the anti-static bar.

7.2 Checking functionalities via the LED's

The color of the status-LED's of the anti-static bar and Ex Status Module show the status of the
anti-static bar. The Ex-Status Module shows only that the fuse is functioning and that voltage is
supplied to the bar = green Blinking, regardless if the bar is in use or on standby.
Table 1, overview status indicators anti-static bar & Ex Status Module
Display Manager
indication
Performax IQ Easy Ex
green
blue
orange
red
grey
grey
* When bar is in RUN mode it will continue to function in Fixed Mode / when in Stand-by it will stay in stand-by
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
"Data logging"
"Clean bar warning level"
LED-indicator
Green Blinking 1 Hz
Green
Red / Green Blinking
1Hz
Red
Red Blinking 5Hz
Off
select On or Off ]
with the slider or with
]
Led-indicator
Ex Status Module
Off
Off
Off
Off
Off
Red
Status
Stand-by
In operation
Clean Bar
High voltage overload
No communication
Fuse on Ex Status
Module defective
select the
High Voltage
output
Off
On
On
On
On/Off*
Off