Dissemble Performax Iq Easy Ex Speed (Slide Bracket); Alternative Brackets; Connecting The Anti-Static Bar; Connect Safety Earthing - ITW SIMCO ION Performax IQ Easy Ex Mode D'emploi

Anti-static bar
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.6 Dissemble Performax IQ Easy Ex Speed (slide bracket)

- Remove the connection cable from the Ex Status Module.
- Unscrew the set screw (no. 6) from the brackets (see Image 5).
- Slide the anti-static bar with brackets from the mounting feet, in the direction of the three
triangles (Mounting method) till it stops, pull the anti-static bar perpendicular to the mounting
feet.

5.7 Alternative brackets

As an alternative to the plastic brackets, 2 additional stainless steel types are available:
Image 5.7.1: Bracket T-slot stainless steel

5.8 Connecting the Anti-static bar

Warning:
- Observe the warnings at the beginning of this chapter.
- The Ex Status Module must be mounted outside the Ex zone.
- Use the Performax IQ Easy Ex Speed always in combination with an Ex Status Module.
Never connect the Performax IQ Easy Ex Speed directly to the power supply, this is
because the Ex Status Module contains the required fuse (0,5 AT / 1500A breaking
capacity)

5.8.1 Connect safety earthing

Image 5.8.1.1: Connecting grounding
Connect the anti-static bar with an M4 eyelet and a grounding wire of at least 4 mm² to a
grounded machine part or grounded terminal.
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
Image 5.7.2: Bracket thread M6x35 stainless steel