8 Maintenance

Warning:
- Disconnect the power supply before carrying out work on the unit.
- The emitters are sharp and can cause injury.

8.1 Regular cleaning of the anti-static bar

Cleaning the ionization bar is the only maintenance that needs to be done. The frequency of
cleaning depends on the amount of pollution in the environment and thus very application
dependent. As a basis you could start with once a month.
The manager and the bar will give a warning if the bar has to be cleaned. By default, this is the
case if the efficiency indicator has dropped to 50%. See also Par 7.
- Clean the emitters, the entire surface of the cast resin and the side strips regularly with a
hard, non-metallic brush. Clean also the Aluminum profile when it is contaminated.

8.2 Cleaning of a heavily contaminated anti-static bar

- Dismount the anti-static bar as described in chapter 5.
- Remove the anti-static bar from the Ex zone.
- Clean the anti-static bar with a suitable cleaning material (e.g. Isopropylalcohol). By very
heavy contamination Veconova 10 can also be used (www.eco-nova.nl).
Let the anti-static bar dry completely before putting back into use.
- Mount the anti-static as described in chapter 5
(If the situation allows it, the antistatic bar may also be cleaned in the position where it is
mounted. The antistatic bar must then be voltage-free).

9 Faults

Warning:
- Disconnect the power supply before carrying out work on the unit.
- Work must only be carried out on the equipment by an electrical engineer with the
relevant training and qualifications.
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4