Les langues disponibles

Table 3, Connection faults
Signaling
LED on anti-static bar
doesn't light up /
Led on Ex Status
Module lights up red
LED on anti-static bar
doesn't light up / Led
on Ex Status Module
doesn't light up
LED on anti-static bar
blinks green 1Hz /
Led on Ex Status
Module doesn't light
up
LED on anti-static bar
lights up red /
Led on Ex Status
Module doesn't light
up
LED on anti-static bar
blinks red / green
(1Hz) and Led on Ex
Status Module
doesn't light up
LED on anti-static bar
blinks red (1 Hz)
though high voltage
on the emitters /
Led on Ex Status
Module doesn't light
up
LED on anti-static bar
blinks red (5 Hz) /
Led on Ex Status
Module doesn't light
up
LED on anti-static bar
lights up green /
Led on Ex Status
Module doesn't light
up
PerformaxIQEasyExPerformaxIQEasyExSpeed_UM_9752153510_NL_D_GB_F_V2_4
Problem
No power on the
emitters
No power on the
emitters
Anti-static bar over
loaded
No/poor ionization,
though High voltage
on the emitters
Voltage not optimal
The communication
with the IQ Easy
platform
has been lost,
high voltage exists
No communication
can be established
with the IQ Easy
platform, but high
voltage exists
Reason
Defective fuse in Ex
Status Module
No power supply
Wiring fault
Anti-static bar is in stand-
by mode
No Remote on/off signal
from Manager
Remote on/off source=
Remote input1
Anti-static bar
contaminated
Anti-static bar mounted
too close to conductive
machine parts
Anti-static bar
contaminated
Emitters are damaged
Anti-static bar incorrectly
positioned
Emitters are covered
Voltage too low
Internal temperature too
high
Problem in the wiring
In the case that it is
connected to the output
5 or 6: these are in
analog I/O
Ionizing bar is not
connected to the IQ Easy
platform
Wiring fault
Solution
Replace fuse.
Type: see chapter 4
Switch on Manager
Check wiring, see 5.8
Set mode to on via the
Manager
Send remote on signal
on I/O connector of the
Manager or select
Remote on/off source =
continuous
Clean Anti-static bar
Reposition the
Anti-static bar
Clean Anti-static bar
Replace the
anti-static bar
Place anti-static bar in
a new position, see 5.3
Remove cover
Check 24 V DC
Manager or increase
diameter of connection
cable or shorten the
connection cable
Check if metal parts are
too close to the
anti-static bar.
Locate fault and remedy ,
see 5.8
Select Serial mode in
the BP of the Manager
choose output 1-4
Connect Ionization bar
to IQ Easy platform
Locate fault and remedy ,
see 5.8