4. Technical specifications

Connection to Manager IQ Easy
Supply voltage
Current Consumption
Connection to machine interface / PLC
24V DC output
Analog remote on/off input
HV OK output
Connection to Chargemaster CM5
User interface:
Status LED
Touchscreen
LED indications
Green flashing, fast
Green flashing, slow
Orange
Red
Red flashing, slow (1Hz)
Red flashing, fast (5Hz)
Environment:
Usage
Temperature
Installation
Protection class
Mechanical:
Length
Width
Height
Weight
Housing
IQComGeneratorConverter_UM_9752103110_NL_D_GB_F_V1_0
M12 5 pin connector (male)
21 – 27 V DC
Max. 0,2A
M12 5 pin connector (female)
21 – 27 V DC, 100 mA max.
15 – 30 V DC = high voltage ON
0 – 5 V DC
= high voltage OFF
24 V DC (±3 V), 50 mA max.
Sud-d25 connector
1 green/red 2 colour LED on the front
On the Manager IQ Easy
Start up
Standby, HV output Chargemaster inactive
Normal operation, HV output Chargemaster
active
1) HV output Chargemaster overloaded,
HV output active
2) Arcing, HV output temporarily not active
1) Eeprom read error, HV output not active
2) Supply voltage too low, HV output
unchanged
3) Chargemaster not connected
4) HV OK output overloaded, HV output
active
5) Warning or Alarm output-current-peak too
high
or too low
6) Warning HV output pulse too long
Communication with Manager IQ Easy lost,
HV output Chargemaster not active
Industrial, indoor use
0 – 55°C
Dust free
IP42
80mm
140mm
30mm
0,3 kg
Aluminium