Combi D 6
1
2
5
6
4
15
Table of contents
Symbols used ...................................................................... 10
Function description ........................................................ 10
Intended use ........................................................................ 11
Fuel supply ........................................................................ 11
Fuel quality .......................................................................... 11
Control panel .................................................................... 12
Room thermostat ............................................................. 12
FrostControl ...................................................................... 12
Initial start-up ................................................................... 12
Winter operation .............................................................. 13
Switching off .................................................................... 13
Maintenance ..................................................................... 14
Fuses .................................................................................. 14
Disposal ............................................................................. 14
Technical data ................................................................... 14
Dimensions ......................................................................... 14
Accessories ....................................................................... 16
10
3
1 Control panel
2 Time switch ZUCB (Accessories)
3 Room temperature sensor
4 Cold water connection
5 Hot water connection
6 Fuel connection
7 Hot air outlets
8 Recirculated air intake
9 Waste gas discharge
10 Exhaust air flue
11 Electronic control unit
12 Water container (10 litres)
13 Burner
14 Heat e xchanger
15 FrostControl (safety/drain valve)
Symbols used
Symbol indicates a possible hazard.
Comment including information and tips.
Function description
The Combi D diesel heater is a warm-air heater with integrated
hot water boiler (10 litres volume). The burner operates fan-
supported, which ensures trouble-free function even when on
the move.
In winter operation the heater can be used to heat the room
and simultaneously warm water. If only warm water is re-
quired, select summer operation.
-
In summer operation, the water contents are heated in
the smallest burner stage. Once the water temperature is
reached, the burner switches off.
-
In winter operation, the unit automatically selects the
required power setting according to the temperature dif-
ference between the temperature set on the control panel
and the current room temperature. When the boiler is filled,
the water is automatically heated as well. The water tem-
perature depends on the selected operational mode and the
heater output.
At a temperature of approximately 3 °C at the automatic
FrostControl safety/drain valve, the valve will open and drain
the boiler.