Maintenance
Step 6 Remove parts for cleaning.
A. Remove Two Thumbscrews and Water Pump
Cover (When Used).
B. Remove the Vinyl Hose Connecting the
Water Pump and Water Distribution Tube
C. Remove Water Pump
• Disconnect the water pump power cord
• Loosen the screws securing the pump-
mounting bracket to the bulkhead
• Lift the pump and bracket assembly off the
mounting screws..
When Used - REMOVE
THUMBSCREWS AND
WATER PUMP COVER
DO NOT SOAK
WATER PUMP MOTOR IN
CLEANER OR SANITIZER
SOLUTIONS
Water Pump Removal
16
D. Remove the Ice Thickness Probe
• Compress the side of the ice thickness probe
near the top hinge pin and remove it from the
bracket.
COMPRESS SIDES OF ICE
THICKNESS PROBE
Ice Thickness Probe Removal
NOTE: At this point, the ice thickness probe can easily
be cleaned. If complete removal is desired follow the ice
thickness probe wire to the bulkhead grommet (exit
point) in the back wall. Pop the bulkhead grommet out of
the back wall by inserting fingernails or a flat object
between the back wall and the grommet and prying
forward. Pull the bulkhead grommet and wire forward
until the connector is accessible, then disconnect the
wire lead from the connector.
Ice Thickness Probe Cleaning
•
Mix a solution of Manitowoc ice machine cleaner and
water (2 ounces of cleaner to 16 ounces of water) in
a container.
•
Soak the ice thickness probe a minimum of 10
minutes.
Clean all ice thickness probe surfaces and verify the ice
thickness probe cavity is clean. Rinse thoroughly with
clean water, then dry completely. Incomplete rinsing and
drying of the ice thickness probe can cause premature
harvest.
Section 4
ICE THICKNESS
PROBE